Are you at risk for cardiovascular diseases?

© 2015 EPFL

© 2015 EPFL

Homocysteine (HcySH) is a potential biomarker of cardiovascular diseases (CVD) including hypertension, coronary heart diseases, stroke and atherosclerosis resulting from the abnormalities in lipoprotein metabolism, oxidative stress and chronic inflammation. Under these conditions, the level of naturally produced HcySH is elevated in blood and becomes essential for the diagnosis and prognosis of CVD. Earlier clinical studies have demonstrated that the increased total plasma HcySH level correlates better than cholesterol with the risk of CVD and also proved to be an appropriate analytical tool for the diagnosis of Alzheimer’s disease (AD).

SEM image of the realized biosensor

Figure: SEM image of the realized biosensor.

Determination of homocysteine (HcySH) is highly beneficial in human physiology and pathophysiology for diagnosis and prognosis of cardiovascular diseases (CVD). Unfortunately, the practicability of the existing methodologies for the determination of HcySH is limited in terms of sample requirements, preparation
time and instrumentation cost. To overcome these limitations, we have developed a new miniaturized electrochemical assay for HcySH in which cytochrome c (cyt c) immobilized on gold nanoparticle (GNP) modified screen printed carbon electrode (SPE) is employed as a biosensing element. The electrochemical characterization of the biosensor (cyt c–GNP–SPE) shows quasi-reversible redox peaks at the potentials 0 and −0.2 V, confirming the cyt c binding. The methodology of quantification is based on the electrochemical oxidation of HcySH by the Fe3+/Fe2+ crevice of cyt c, observed at a potential of +0.56 V. Using the amperometric technique, the detection limit of HcySH is found to be 0.3 ± 0.025 μM in the linear range between 0.4 μM and 700 μM, with a sensitivity of 3.8 ± 0.12 nA μM−1 cm−2. The practical application of the present assay is validated through the measurement of HcySH in blood plasma samples and the selectivity is ensured by eliminating the impact of the common interfering biological substrates using a Nafion membrane. This biosensor shows striking analytical properties of good repeatability, reproducibility (2.85% SD) and high stability (83% of its initial current response after 4 weeks). This work paves the way for cheap, efficient and reliable point-of-care biosensors for screening one of the major causes of deaths both in the developed and developing countries.

Check the corresponding publication: PDF External link: doi:10.1039/c5an00752f